Type 2 · 1.5 fy
Develops the specified tensile strength of the bar (1.5 fy for Grade 42 rebar).
Minimum with Grade 42 rebar: 63 kg/mm².
EN ES
Hybrid Coupler · Patented technology
Develops the specified tensile strength of the bar (1.5 fy for Grade 42 rebar). Cold-crimped with the G7K tool, with no threading or heating of the bar. Made in Mexico.
ACI 318 · NTC-CDMX
Type 2 · 1.5 fy
Develops the specified tensile strength of the bar (1.5 fy for Grade 42 rebar).
Minimum with Grade 42 rebar: 63 kg/mm².
Type 1 · 1.25 fy
Develops at least 1.25 times the specified yield strength of the bar (1.25 fy).
Minimum with Grade 42 rebar: 52.5 kg/mm².
Tested under ACI 318S-14 (section 25.5.7.1) and NTC-CDMX (section 6.6.1.6).

Installation
The bar is not cut, threaded or heated: it keeps its full cross-section and properties.
No bar-end preparation and no perfect cut needed.
The coupler is placed over the joint between the two bars.
The G7K tool cold-crimps the coupler. The crimp mark allows visual inspection.
Patented technology
A high-strength steel sleeve with an inner polymer layer. When crimped, the polymer seals the splice and keeps water out.

Data sheet
| Model | Bar size | Bar (mm) | Length (cm) | Outer Ø (mm) | Inner Ø (mm) | Weight (kg) |
|---|---|---|---|---|---|---|
| CHT2-S06 | #6 | 19.0 | 8 | 36 | 26 | 0.42 |
| CHT2-S08 | #8 | 25.4 | 12 | 43 | 30 | 0.76 |
| CHT2-S10 | #10 | 31.8 | 16 | 57 | 38 | 1.38 |
| CHT2-S12 | #12 | 38.1 | 18 | 64 | 44 | 1.75 |
Type 1 and Type 2 have the same dimensions. Capacity: Type 2 = 1.5 fy · Type 1 = 1.25 fy (Grade 42 rebar).
Evidence
Tensile tests in EMA-accredited laboratories. Type 2 minimum with Grade 42 rebar: 63 kg/mm² (1.5 fy).
Bar size #6 19.0 mm · 3/4"
74.5 kg/mm²
Range: 74.5
Atizapán–Atlacomulco Highway
Bar size #8 25.4 mm · 1"
81.8 kg/mm²
Range: 72.5–81.8
IKEA Guadalajara · Heineken Grajales · Atizapán–Atlacomulco Highway
Bar size #10 31.8 mm · 1 1/4"
69.5 kg/mm²
Range: 65.0–69.5
IKEA Guadalajara · Geotecnia test 2022
Bar size #12 38.1 mm · 1 1/2"
71.0 kg/mm²
Range: 63.0–71.0
IKEA Guadalajara · Los Encinos Hospital
Laboratory and project details in Lab tests. Full reports available on request.
FAQ
For #6, #8, #10 and #12 rebar (19.0 to 38.1 mm).
No. It is not saw-cut square, threaded or heated: you just align the bars, slide on the coupler and crimp.
The G7K crimping tool: portable, 110 V, with dies for each bar size. It works in vertical or horizontal position.
Visually: crimping leaves a visible mark on the coupler.
ACI 318 allows Type 2 mechanical splices at any location, except as noted in Chapter 18. The decision rests with the project's structural engineer.
Looking for the other type? See Type 1 coupler (1.25 fy).
We will send you the data sheet and a quote by bar size. If needed, we can schedule a technical visit.