Type 1 mechanical rebar coupler (1.25 fy)

Develops at least 1.25 times the specified yield strength of the bar (1.25 fy). Cold-crimped with the G7K tool, with no threading or heating of the bar. Made in Mexico.

Request a quote See specifications

ACI 318 · NTC-CDMX

What is a Type 1 mechanical splice?

Type 2 · 1.5 fy

Develops the specified tensile strength of the bar (1.5 fy for Grade 42 rebar).

Minimum with Grade 42 rebar: 63 kg/mm².

Type 1 · 1.25 fy

Develops at least 1.25 times the specified yield strength of the bar (1.25 fy).

Minimum with Grade 42 rebar: 52.5 kg/mm².

Tested under ACI 318S-14 (section 25.5.7.1) and NTC-CDMX (section 6.6.1.6).

Concrete column starter bars with MOLBER Hybrid Couplers installed
Column starter bars with couplers installed.

Installation

Align, slide and crimp.

The bar is not cut, threaded or heated: it keeps its full cross-section and properties.

  1. 01

    Align

    No bar-end preparation and no perfect cut needed.

  2. 02

    Slide

    The coupler is placed over the joint between the two bars.

  3. 03

    Crimp

    The G7K tool cold-crimps the coupler. The crimp mark allows visual inspection.

Patented technology

Why hybrid?

A high-strength steel sleeve with an inner polymer layer. When crimped, the polymer seals the splice and keeps water out.

Worker in a safety harness crimping a coupler high on a column with the G7K tool

Data sheet

Type 1 models.

ModelBar sizeBar (mm)Length (cm)Outer Ø (mm)Inner Ø (mm)Weight (kg)
CHT1-S06 #6 19.0 8 36 26 0.42
CHT1-S08 #8 25.4 12 43 30 0.76
CHT1-S10 #10 31.8 16 57 38 1.38
CHT1-S12 #12 38.1 18 64 44 1.75

Type 1 and Type 2 have the same dimensions. Capacity: Type 2 = 1.5 fy · Type 1 = 1.25 fy (Grade 42 rebar).

Evidence

Lab results.

Tensile tests in EMA-accredited laboratories. Type 1 minimum with Grade 42 rebar: 52.5 kg/mm² (1.25 fy).

Bar size #6 19.0 mm · 3/4"

74.5 kg/mm²

min. 52.5

Range: 74.5

Atizapán–Atlacomulco Highway

Bar size #8 25.4 mm · 1"

81.8 kg/mm²

min. 52.5

Range: 72.5–81.8

IKEA Guadalajara · Heineken Grajales · Atizapán–Atlacomulco Highway

Bar size #10 31.8 mm · 1 1/4"

69.5 kg/mm²

min. 52.5

Range: 65.0–69.5

IKEA Guadalajara · Geotecnia test 2022

Bar size #12 38.1 mm · 1 1/2"

71.0 kg/mm²

min. 52.5

Range: 63.0–71.0

IKEA Guadalajara · Los Encinos Hospital

Laboratory and project details in Lab tests. Full reports available on request.

FAQ

What engineers ask.

Which bar sizes are available?

For #6, #8, #10 and #12 rebar (19.0 to 38.1 mm).

Does the bar need preparation?

No. It is not saw-cut square, threaded or heated: you just align the bars, slide on the coupler and crimp.

What equipment is needed?

The G7K crimping tool: portable, 110 V, with dies for each bar size. It works in vertical or horizontal position.

How is the splice inspected?

Visually: crimping leaves a visible mark on the coupler.

Where can Type 1 be used?

Location requirements are set by the applicable code (ACI 318, NTC-CDMX) and defined by the structural engineer. If the project requires developing the tensile strength of the bar, use Type 2.

Looking for the other type? See Type 2 coupler (1.5 fy).

Have a project coming up?

We will send you the data sheet and a quote by bar size. If needed, we can schedule a technical visit.

Request a quote WhatsApp +52 442 247 0473